18 Warranty Time Soft Starter Control Panel 37kw for Submersible Pump
Overview Package Size 76.00cm * 57.50cm * 41.50cm Package Gross Weight 40.000kg Detailed Photos18 warranty time Soft Sta
Overview
ZJR2 device type can work without three-phase AC motor in the process of starting too big acceleration torque,and power supply system plays a protection from excessive current harvest dynamic impact role, has the following characteristics:
1. 16 SCM control,intelligent all-digital display;2. Can be put into practice a soft starter control multiple motors;3. Starting modes: Current limiting starter, Voltage ramp start, Kick start +current-limiting start, Kick start +voltage ramp start.Current ramp start.Voltage current-limiting double closed -loop start.4. Free stop and soft stop, The stop time from 0 to 60 seconds can be arbitrary choosed.5. Over current,Overload.Open phase,instantaneous stop and other fault protection.with the flow,over loading,lack phase,instantaneous stop,and other malfunction protection;6. Easy installation,simple operation,strong function and reasonable prices.
Company Profile
Certifications
FROM OUR CUSTOMER
Basic Info.
Model NO. | ZJRG-37 |
Signal | The Soft Starter Can Work When The Motor Starts |
Function | Automatic Control, Protection |
Certification | CCC, ISO: 9001, CE |
Condition | New |
Customized | Customized |
Material | Iron Shell |
Net Weight | 30kg |
Starting Times | It Is Recommended Not to Exceed 20 Times Per Hour. |
Packing Way | Wooden Box |
OEM | Yes |
Gross Weight for Each Carton | 40kg |
Input Voltage | Three Phase 380V-15% ~ 415+10% |
Power Range | 5.5kw~600kw |
Color | Gray |
Input Frequency | 50/60Hz |
Adaptive Motor | Squirrel-Cage Three-Phase Asynchronous Motor |
Transport Package | Stardard Export Package |
Specification | CCC CE |
Trademark | CHZIRI |
Origin | Wenzhou, Zhejiang |
HS Code | 8537101990 |
Production Capacity | 300PCS/Month |
Packaging & Delivery
Package Size 76.00cm * 57.50cm * 41.50cm Package Gross Weight 40.000kgProduct Description
Detailed Photos18 warranty time Soft Starter Control Panel 37kw for Submersible PumpZJR2 Series Soft Starter control panel motor applies to centrifuges,blower,compressor,transport planes,mixer,rolling ball mill broken machines and mechanical equipment motor starter.ZJR2 device type can work without three-phase AC motor in the process of starting too big acceleration torque,and power supply system plays a protection from excessive current harvest dynamic impact role, has the following characteristics:
1. 16 SCM control,intelligent all-digital display;2. Can be put into practice a soft starter control multiple motors;3. Starting modes: Current limiting starter, Voltage ramp start, Kick start +current-limiting start, Kick start +voltage ramp start.Current ramp start.Voltage current-limiting double closed -loop start.4. Free stop and soft stop, The stop time from 0 to 60 seconds can be arbitrary choosed.5. Over current,Overload.Open phase,instantaneous stop and other fault protection.with the flow,over loading,lack phase,instantaneous stop,and other malfunction protection;6. Easy installation,simple operation,strong function and reasonable prices.
Item | Item Description | ||
Input Power Supply | Input Voltage | Three Phase 380V-15% ~ 415+10% | |
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode | 1) Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control; 5) Operation panel + external + COM control; 6) Operation panel + COM control; 7) COM control; 8) No start or stop operation. | ||
Start Mode | 1) Current-limiting start; 2) Voltage ramp start; 3) Kick start + current-limiting start; 4) Kick start + voltage ramp start; 5) Current ramp start; 6) Voltage current-limiting double closed-loop start. | ||
Stop Mode | 1) Soft stop; 2) Free stop. | ||
Protective Function | Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over voltage protection for power voltage; 11) Protection for fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals. | ||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude | Below 3000M. It have to rise the rate power when the altitude is more than 3000M. | ||
Ambient Temperature | -30~+55ºC | ||
Ambient Humidity | ≤90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Natural wind cooling. |
Company Profile
Certifications
FROM OUR CUSTOMER
Send to us