Mqtt Industry 4.0 Controller for Iiot Control PLC Pr
HomeHome > Products > Programmable Logic Controller > Mqtt Industry 4.0 Controller for Iiot Control PLC Pr
Mqtt Industry 4.0 Controller for Iiot Control PLC Pr

Mqtt Industry 4.0 Controller for Iiot Control PLC Pr

About Programming Cable. Pleased to inform you that our micro plc is developed 100% by ourself ,and they are incompatibl
Basic Info.
Model NO. PR-26AC-R-N
Ethernet Port Yes
Expansion Yes(16PCS in Max)
Email No
Datalogger SD Socket Yes
4G/GSM/GPRS No
Supply AC 110V- 240V
Weight Approx. 400g
Output 10 Relay Outputs
Input 16 Di AC
Transport Package Standard Export Carton
Specification 133mm*90mm*60mm
Trademark RIEVTECH
Origin Nanjing, China
HS Code 8537101190
Product Description

About Programming Cable.

Pleased to inform you that our micro plc is developed 100% by ourself ,and they are incompatible with any other brands plc's programming cable. so we strongly suggest you also purchase the programming cable when you purchase the CPU units,we have two types programming cables,one is USB CABLE (USB communication module PC and ELC units); the other is RS232 CABLE (RS232 programming cable between PC and PR units,or connection cable between CPU and HMI with standard RS232 port).Without programming cable, you can not set up connection/communication between PC and PLC, further, you naturally can not make programme via PC, and surely unable to download your programme to our PLC.

About Programmable Software.

Programming software For PR Series is xLogicSoft.Programming software For EXM Series is eSmsConfig.Download link:https://rievtechplc.en.made-in-china.com
GENERAL SPECIFICATIONS
Timers: 1024
Counters: 1024
Function Blocks: 1024
Operation temp.: -20°C - 55°C
Storage: -40°C - 70°C
Protection: IP20 (Non-waterproof)
RTC accuracy: MAX ±2S/day
RTC Backup at 25 °C: 20 days
Program and settings Backup: 10 years
Data Power-off retentivity: 10 years
Modify parameters via keypad LCD: YES
Dimensions: 133*90*60(Unit:mm)
Certificate: CE
Installation: 35-DIN rail or screw for installation
Expansion capacity: 16 modules (PR-E-16)
Password protection: 4-digit number password protection or disable program upload function
Communication interface: 1 RS232 Port (COM0) & 1 RS485 port (COM1 external) available via optional accessory, 1 built-in RS485 (C0M2), 1Ethernet port.
Communication protocol: Modbus RTU/ASCII, Modbus TCP

Technical Index
Power supply:
Nominal voltageAC110V-240V
Operating limits AC85 - 265 V
The main frequency range 47-63Hz
Max. absorbed power50mA (85V ac) ; 40mA (265V ac)
Isolation voltage1780V AC
Protection against polarity inversionsYes
Input parameters:
Input No16( I1-IG)
Digital input 16 ( I1-IG)
Analogue input None
Input voltage AC110-240V
Input signal0 AC0-40V;<0.03mA
Input signal1 AC79-240V; >0.06mA
Input Response TimeDelay time at 0 to 1:
120V AC :Typ. 50 ms
240V AC :Typ. 30 ms
Delay time at 1 to 0:
120V AC :Typ. 90 ms
240V AC :Typ.100 ms
Maximum counting frequencyTyp. 4Hz
Sensor typeContact or 3-wire PNP
Isolation between power supply and inputsNone
Isolation between inputsNone
Protection against polarity inversionsYes
Input typeResistive
Isolation between power supply and inputsNone
Isolation between inputsNone
Output
5A Relay 6 outputs from Q1 to Q6
Max. breaking voltage CE:AC 250 V/DC 30 V 5A
UL:AC 250 V/DC 30 V 3A
Electrical durability Expectancy105 Operations at Rated Resistive Load
Mechanical life107 Operations at No Load condition
Response timeOperate Time: 15 mSec. Max.
Release Time: 10 mSec. Max.
Built-in protectionsAgainst short-circuits: None
Against overvoltages and overloads: None
10A Relay 4 outputs from Q7 to QA
Max. breaking voltage CE:AC 250 V/DC 30 V 10A
UL:AC 250 V/DC 28 V 5A
Max. Allowable Power Force1250VA
Electrical durability Expectancy105 Operations at Rated Resistive Load
Mechanical life107 Operations at No Load condition
Response timeOperate Time: 15 mSec. Max.
Release Time: 10 mSec. Max.
Built-in protectionsAgainst short-circuits: None
Against overvoltages and overloads: None
Communication ports parameters:
COM0_TTL portCan be used as program port with PR-RS232&PR-USB;
Also can be convert to RS232 port with PR-RS232
Can be convert to RS485 port with PRO-RS485
Note:Need move away the expand cover to use it
Can be used as mobus master or slave
Built-in RS4851 built-in RS485 port (Terminal A+,B-)
Can be used as mobus master or slave
Ext RS485Need use with PR-E-RS485 module
Can be used as mobus master or slave
Ethernet port: Built-In(10M/100M),
1.Can be used as program or communication
2.Can be used as mobus master or slave
Monitoring webserver pageYes
Xlogic<--->Xlogic(by Ethernet)1 xlogic works as tcp server can connect with 8 tcp client xlogics or other tcp devices.
Xlogic<--->Ethernet/Internet:1 xlogic works as TCP clients can connect with 8 different tcp servers separately in maximum
Other parameter
WeightApprox.400g

Dimension

Mqtt Industry 4.0 Controller for Iiot Control PLC Pr-26AC-R-N