W713b IP54 Intelligent Pump Constant Pressure Controller
HomeHome > Products > Intelligent Pump Controller > W713b IP54 Intelligent Pump Constant Pressure Controller
W713b IP54 Intelligent Pump Constant Pressure Controller

W713b IP54 Intelligent Pump Constant Pressure Controller

About Bedford Guangzhou Bedford Electric Equipment Co., Ltd. has focused on automatic water pump controllers and solar p
Basic Info.
Model NO. W713B
Link of Transformation AC-DC-AC Variable-Frequency Drive
Nature of DC Power Voltage Variable-Frequency Drive
Function Pump Special
Brand Bedford
Input Voltage 1pH 220V or 3pH 380V
Color Black
Protection Rate IP54
Output Voltage 0~220/380V Three Phase
Output Power 0.75~18.5kw
Transport Package Wooden Cases or as Customes′ Requirements
Specification Depend on model
Trademark BEDFORD
Origin Guangzhou
HS Code 9032899090
Production Capacity 5000 Pieces /Month
Product Description

About Bedford

Guangzhou Bedford Electric Equipment Co., Ltd. has focused on automatic water pump controllers and solar pump inverters since 2003. We aim to provide users with innovative inverter solutions for stable water supply systems worldwide. It is essential to source quality automatic water pump controllers from a reliable water pump manufacturer to improve the automation level of water supply systems and reduce equipment maintenance and labor costs. The W713B series pump-mounted controller has been recognized and appreciated by our customers since its launch.


Waterproof New Style Constant Pressure Variable Speed Water Pump Controller -IP54
is suitable for full-automatic operation, with characteristics of high quality, multi-functional, low noise and strong commonality etc.There are no special demands for peripherals, it mainly use normal components, for example: Water detection use transducer, transmitter (include water level transmitter, temperature transmitter, etc. ) or inductive remote transmission pressure gauge, with output of 4~20mA, 0~5VDC and 0~10 VDC standard signal.
Features:

CategoryContentW713B
Photo for Reference
Pressure OptimizationPressure StabilityThe pressure change curve is more stable, and the frequency change is smaller after stabilization
Alternate TransitionYes, the transition tends to be smooth and excessive (the transitional pump looks at the difference between the given pressure L and the feedback pressure P to adjust the frequency, and it will stop when L-P<0.2bar. If the water consumption suddenly increases at this time, the L-P>0.2 bar, alternating water pumps will speed up the frequency regulation pressure, when L-P=0.2bar, slowly adjust the frequency for a smooth transition)
ModeControl ModeConstant pressure, Constant differential pressur,Constant temperature, Constant differential temperature
Linkage
Mode
Synchronize, Master-slave, Big-small pump, One duty one standby, One VFD drive two pumps
Manual/
auto Mode Switching
Can be switched by button or terminal.
Button switch: press the and buttons at the same time for manual/auto switch (also switchable in case of failure)
Terminal switching:
S2-COM off: auto control
S2-COM on:manual control
In manual control, the manual frequency can be adjusted through the up and down buttons, and the influence of pressure is shielded, which is more comprehensive
Alternating Mode
  1. Alternate by time (Alternate when time comes to sleep)
  2. Alternate sleep and wake up, and alternate by time
Upper and Lower Pool ControlAvailable (S1~S4 terminal control)
Independent Start and Stop ControlAvailable, start and stop is controlled by the inverter (can be controlled by panel or S4 terminal)
Outward ExpansionGeneral Frequency Converter (such as PLC)Compatible with this mode
Connect the Touch Screen of BEDFORD Available
Third-party DevicesDirect connection
(Mob Bus RTU communication protocol)
External Interface FeaturesAnalog Input
Digital Input4-way
1. Electronic contact gauge control
2. Manual/auto control
3. Terminal run/stop
4. Water level control (low water level)
5. Upper and lower pool control
6. One driving two fault input
Digital Output
  1. way relay output selection
0: Error or external fault;
1: Forward running (including zero-speed running);
2: Upper limit frequency reaching;
3: Stop status;
4: Lower limit frequency reaching;
5: The frequency is not equal to zero;
6: Actual pressure on the outlet side reaching high water pressure alarm value;
7: Actual pressure on the outlet side decreases to low water pressure alarm value;
8: Actual temperature on the outlet side reaching high water temperature alarm value;
9: Actual temperature on the outlet side decreases to low water temperature alarm value;
10: One driving two RO function, for variable frequency pump control
11: One driving two RO function, for power frequency pump control
ButtonKeyboard Touch Touch the button: feel better
Other FeaturesMulti-linkage Max realize up to 5 pumps linkage water supply operation
Sleep FunctionUnmanned water automatic sleep, better energy saving effect
Freeze-proofing FunctionSuitable for low temperature frost climate
Anti-clogging FunctionPrevent and remove pipe blockage
Power On RestartAutomatic continuous water supply, power interruption during operation, and automatic restart when there is a call
Master Fault Shift AutomaticallyRealize unmanned monitoring, host failure, uninterrupted water supply
Day-Part Function1. 3 independent day-part control, up to 7 day-part achieved when define separated;
2. One Duty One Standby Day-part Function: 3 independent day-part time section contro.
Multiple Water Supply Failure Alarm FunctionsHigh water pressure, low water pressure, low water level, open sensor and other fault alarms
Multiple Fault Protection FunctionsOvercurrent, overvoltage, under voltage, phase loss, overload and other protection functions